Gurko Underground Car Park
- Client
- Sofia Municipality - SREDETS DISTRICT
- Architecture
- VAMOS Ltd.
- Facility length
- 178m
- Facility width
- 28m
- Facility height (depth)
- 11 m (3 underground levels)
- Design
- Structures
- Building technology
- RC diaphragm walls and roof slabs built by the Milan method
- Main structural material
- reinforced concrete
- Characteristics
- Construction without stopping the traffic above the car park
Built by the Milan method - Phase/stage
- In design